This project examines early detection of an inlet-pipe blockage in a Roots blower. The dataset contains eight sensor measurements, more than 450,000 timestamped records, and weak-anomaly observations from operators.
Data and model comparison
Logistic regression, a neural-network classifier, random forest, GBDT, SVDD and KNN all achieved 100% accuracy on the validation set. This classification result does not establish warning timeliness or the false-alarm rate in deployment.
From predictions to warnings
A Poisson hypothesis test on daily anomaly counts converts classifier outputs into an alarm decision. KNN triggered on December 13, nearly one month before the blockage alarm, matching weak-anomaly entries in the maintenance log.
Explore the Poisson threshold
Interactive illustration
Background rate and alarm threshold
Adjust the assumed rate and significance level. The displayed counts are synthetic.
Beyond this case
Anomaly detection can inform statistical process control and model predictive control. Transfer to manufacturing requires separate validation of temporal generalization, rare faults, uncertainty calibration and control safety. This case demonstrates equipment warning, not a validated closed-loop semiconductor-fab controller.